BROCADE RUCKUS BR-DCX8514-0001 FC16-32 For Sale

BROCADE RUCKUS BR-DCX8514-0001 FC16-32
When you click on links to various merchants on this site and make a purchase, this can result in this site earning a commission. Affiliate programs and affiliations include, but are not limited to, the eBay Partner Network.


Buy Now

BROCADE RUCKUS BR-DCX8514-0001 FC16-32:
$24378.00

Brocade DCX 8510 Backbone SpecificationsSystems ArchitectureChassis Single chassis: Up to 512 (Brocade DCX 8510-8) or 256 (Brocade DCX 8510-4) 16 Gbps (E, F, D, M, andEX) Fibre Channel ports using 64-port 16 Gbps Fibre Channel blades.Multi-chassis with UltraScale ICL ports: Up to 6,144 16 Gbps Fibre Channel ports; UtraScale ICL ports (32 or16 per chassis, optical QSFP) connect up to nine chassis in a full mesh topology or up to 12 chassis in a coreedge topology. Each Brocade DCX 8510 chassis that connects to four or more Brocade DCX 8510 chassis viaUltraScale ICLs requires an Enterprise ICL license.Control processor Redundant (active/standby) control processor modulesScalability Full fabric architecture of 239 switchesCertified maximum 6,000 active nodes; 56 switches, 19 hops in Brocade Fabric OS® fabrics; 31 switches, larger fabrics certified asrequiredSpecial-purpose blades Brocade FX8-24 Extension Blade provides SAN extension over IP networks (12 8 Gbps Fibre Channel ports,10 1 GbE ports with license option for up to two 10 GbE ports per blade; up to four blades).Brocade FCOE10-24 Blade provides Fibre Channel over Ethernet (FCoE) and Data Center Bridging (DCB) forend-of-row server connectivity, delivering line-rate 10 Gbps performance across 24 ports.Performance Fibre Channel: 2.125 Gbps line speed, full duplex; 4.25 Gbps line speed, full duplex; 8.5 Gbps line speed, fullduplex; 10.53 Gbps line speed, full duplex; 14.025 Gbps line speed, full duplex; auto-sensing of 2, 4, 8, and 16Gbps port speeds; 10 Gbps and optionally programmable to fixed port speedISL trunking Frame-based trunking with up to eight 16 Gbps ports per ISL trunk; up to 128 Gbps per ISL trunkExchange-based load balancing across ISLs with DPS included in Brocade Fabric OSChassis bandwidth Brocade DCX 8510-8: 10.2 Tbps per chassis(512 ports × 16 Gbps data rate + 2.048 Tbps UltraScale ICL bandwidth)Brocade DCX 8510-4: 5.1 Tbps per chassis(256 ports × 16 Gbps data rate + 1.024 Tbps UltraScale ICL bandwidth)Slot bandwidth 512 Gbps (data rate)Local switching bandwidth 512 Gbps for Brocade FC16-32: 32 ports × 16 Gbps (data rate)768 Gbps for Brocade FC16-48: 48 ports × 16 Gbps (data rate)1,024 Gbps for Brocade FC16-64: 64 ports × 16 Gbps (data rate)UltraScale ICL bandwidth Brocade DCX 8510-8: 2.048 Tbps; 32 UltraScale ICL ports provide the equivalent of 128 16 Gbps ports.Each UltraScale ICL port provides 64 Gbps bandwidth over a QSFP (4×16 Gbps) link.Brocade DCX 8510-4: 1.024 Tbps; 16 UltraScale ICLs provide the equivalent of 64 16 Gbps ports. EachUltraScale ICL port provides 64 Gbps bandwidth over a QSFP (4×16 Gbps) link.Both models: Frame-based trunking is enabled between four UltraScale ICLs. DPS distributes exchanges acrossall frame trunks.Switch latency Locally switched port latency is 700 ns; blade-to-blade latency is 2.1 µsec; encryption/compression is 5.5 µsecper node; Forward Error Correction (FEC) adds 400 ns between E_Ports (enabled by default).Maximum frame size 2,112-byte payloadFrame buffers 8,192 per 16-port group on 32-port and 64-port blades and up to 8,192 per 24-port group on 48-portblades, dynamically allocatedClasses of service Class 2, Class 3, Class F (inter-switch frames)Fibre Channel port types D_Port (ClearLink Diagnostic Port), E_Port, EX_Port, F_Port, M_Port (Mirror Port); optional port type controlData traffic types Fabric switches supporting unicast5Media types • 16 Gbps: Brocade FC16-64 requires Brocade hot-pluggable QSFP connector; 4×16 Gbps SWL, MPO1×12 ribbon cable connector (66 m OM3, 100 m OM4; FC16-64 QSFPs support only 4/8/16 Gbps [not 2Gbps or 10 Gbps])• 16 Gbps: Brocade FC16-32 and -48 require Brocade hot-pluggable SFP+, LC connector; 16 Gbps SWL,LWL, ELWL• 10 Gbps: Brocade FC16-32 and -48 require Brocade hot-pluggable SFP+, LC connector; 10 Gbps SWL,LWL; Brocade FCOE10-24 requires hot-pluggable, Brocade 10 GbE SFP+ with any combination of ShortReach (SR) and Long-Reach (LR) optical transceivers• 8 Gbps: Brocade FC16-32 and -48 and Brocade FX8-24 require Brocade hot-pluggable SFP+, LCconnector; 8 Gbps SWL, LWL, ELWL• UltraScale ICL QSFP: Brocade CR16-8 and CR16-4 require Brocade hot-pluggable QSFP, MTP connector;4×16 Gbps SWL (50 m OM3, 100 m OM4, and 2 km QSFP for long distances)• Fibre Channel distance subject to fiber-optic cable and port speedUSB 1 USB port per control processor for firmware download, support save, and configuration upload/downloadFabric services Brocade Fabric Vision technology; Monitoring and Alerting Policy Suite (MAPS); Flow Vision; Brocade AdvancedPerformance Monitoring (APM) (including Top Talkers for E_Ports, F_Ports, and Fabric mode); Brocade AdaptiveNetworking (Ingress Rate Limiting, Traffic Isolation, QoS); Bottleneck Detection; Brocade Advanced Zoning(default zoning, port/WWN zoning, broadcast zoning); Dynamic Fabric Provisioning (DFP); Dynamic PathSelection (DPS); Brocade Extended Fabrics; Enhanced BB credit recovery; Brocade Fabric Watch; FDMI; FlowVision; Frame Redirection; Frame-based Trunking; FSPF; Integrated Routing; IPoFC; Brocade ISL Trunking;Management Server; Monitoring and Alerting Policy Suite (MAPS); Configuration and Operational MonitoringPolicy Automation Services Suite (COMPASS); NPIV; NTP v3; Port Fencing; Registered State ChangeNotification (RSCN); Reliable Commit Service (RCS); Brocade Server Application Optimization (SAO); SimpleName Server (SNS); Virtual Fabrics (Logical Switch, Logical Fabric)Extension Supports DWDM, CWDM, and FC-SONET devices; Fibre Channel, in-flight compression (Brocade LZO) andencryption (AES-GCM-256) BB credit recovery; FCIP, Adaptive Rate Limiting (ARL), data compression, FastWrite, read/write Tape Pipelining, QoSFICON FICON cascading (Brocade Fabric OS: Brocade DCX 8510-8, DCX 8510-4); support for lossless DLS;FICON CUP; Advanced Accelerator for FICON (FICON Global Mirror and XRC emulation and read/write TapePipelining). The Brocade FC8-64 and FC16-64 blades must be in a logical switch that is not being used forFICON connections; they do not support FICON.High AvailabilityArchitecture Passive backplane; redundant active/passive control processor; redundant active/active core switching blades;redundant WWN cardsChassis power Two 2,000 W AC power supply modules (100 to 240 V auto-sensing), 2N redundancy; Brocade DCX 8510-8supports two additional power modulesCooling Brocade DCX 8510-8: Three blower assembly modules (two required for operation)Brocade DCX 8510-4: Two blower assembly modules (one required for operation)Solution availability Designed to provide 99.999 percent uptime capabilities; hot-pluggable redundant power supplies, fans, WWNcards, processors, core switching, port blades, and optics; online diagnostics; non-disruptive firmware downloadand activationManagementManagement HTTP, SNMP v1/v3 (FE MIB, FC Management MIB), SSH; Auditing, Syslog; Brocade Advanced Web Tools,Brocade Network Advisor SAN Enterprise or Brocade Network Advisor SAN Professional Plus; Command LineInterface (CLI); SMI-S compliant; Administrative Domains; trial licenses for add-on capabilitiesSecurity AES-GCM-256 encryption on ISLs; DH-CHAP (between switches and end devices), FCAP switchauthentication; FIPS 140-2 L2-compliant, HTTPS, IPsec, IP filtering, LDAP with IPv6, OpenLDAP, PortBinding, RADIUS, User-defined Role-Based Access Control (RBAC), Secure Copy (SCP), Secure RPC, SFTP,SSH v2, SSL, Switch Binding, TACACS+, Trusted SwitchBrocade DCX 8510 Backbone Specifications (continued)6Management access 10/100/1000 Ethernet (RJ-45) per control processor, in-band over Fibre Channel; serial port (RJ-45) and oneUSB per control processor module; call-home integration enabled through Brocade Network AdvisorDiagnostics Built-in flow generator, ClearLink optics and cable diagnostics, including electrical/optical loopback, link traffic/latency/distance; POST and embedded online/offline diagnostics, including environmental monitoring, FCpingand Pathinfo (FC traceroute), flow mirroring, frame viewer, non-disruptive daemon restart, port mirroring, opticshealth monitoring, power monitoring (16 Gbps blades-only), RAStrace logging, and Rolling Reboot Detection(RRD)Mechanical SpecificationsEnclosure Rear panel-to-door airflow; Brocade DCX 8510-4 ships with 1U exhaust shelfMounting Rack-mountable in a standard 19-inch EIA cabinetSize Brocade DCX 8510-8Width: 43.74 cm (17.22 in.)Height: 62.23 cm (24.50 in., 14U)Depth (without door): 61.29 cm (24.13 in.)Depth (with door): 73.20 cm (28.82 in.)Brocade DCX 8510-4Width: 43.74 cm (17.22 in.)Height: 35.60 cm (14 in., 8U) plus 4 cm exhaust shelf (1.75 in, 1U)Depth without door: 61.29 cm (24.09 in.)Depth with door: 73.20 cm (28.82 in.)System weight Brocade DCX 8510-8103.38 kg (227.9 lb) for 512-port configuration fully populated37.30 kg (82.20 lb) for chassisBrocade DCX 8510-469 kg (152 lb) for 256-port configuration fully populated25.4 kg (56 lb) for chassisEnvironmentTemperature Operating: 0°C to 40°C (32°F to 104°F)Non-operating: –25°C to 70°C (–13°F to 158°F)Humidity Operating: 5% to 93% RH non-condensing at 40°C (104°F) with a maximum gradient of 10% per hourNon-operating: 10% to 93% RH non-condensing at 70°C (158°F)Altitude Up to 3,000 meters (9,842 feet)Shock Operating: 20 g, 6 ms, half sineNon-operating: 33 g, 11 ms, half sineVibration Operating: 0.5 g p-p, 5 to 500 HzNon-operating: 2.0 g p-p, 5 to 500 HzHeat dissipation Brocade DCX 8510-8512-port configuration: 7,462 BTU/hrBrocade DCX 8510-4256-port configuration: 4,182 BTU/hrCO2 emissions Brocade DCX 8510-88.9 metric tonnes per year (max: with 384 ports using eight 48-port blades)Brocade DCX 8510-44.9 metric tonnes per year (max: with 192 ports using four 48-port blades)Brocade DCX 8510 Backbone Specifications (continued)7PowerSupported power range VoltageRange: 85 to 264 VAC Auto-voltNominal: 100 to 240 VACPower85 to 132 VAC: 1,000 W180 to 264 VAC: 2,000 WIn-rush current 60 Amps maximum, peakFrequency 47 to 63 Hz (Nominal: 50 to 60 Hz)Brocade DCX 8510 Backbone Specifications (continued)© 2017 Brocade Communications Systems, Inc. All Rights Reserved. 03/17 GA-DS-1564-14Brocade, the B-wing symbol, and MyBrocade are registered trademarks of Brocade Communications Systems, Inc., in the UnitedStates and in other countries. Other brands, product names, or service names mentioned of Brocade Communications Systems, Inc.are listed at Other marks maybelong to third parties.Notice: This document is for informational purposes only and does not set forth any warranty, expressed or implied, concerningany equipment, equipment feature, or service offered or to be offered by Brocade. Brocade reserves the right to make changesto this document at any time, without notice, and assumes no responsibility for its use. This informational document describesfeatures that may not be currently available. Contact a Brocade sales office for information on feature and product availability.Export of technical data contained in this document may require an export license from the United States government.Corporate HeadquartersSan Jose, CA USAFor information about supported SAN standards, visit www.brocade.com/sanstandards.For information about switch and device interoperability, visit www.brocade.com/interoperability.For information about hardware regulatory compliance, visit www.brocade.com/regulatorycompliance.


Buy Now

Related Items:

Ruckus Brocade ICX-FAN10-E ICX Switch Fan 60-1002274-03 picture

Ruckus Brocade ICX-FAN10-E ICX Switch Fan 60-1002274-03

$30.00



NEW Ruckus ICX-FAN11 Fan Tray module assembly For Brocade ICX7150-48ZP Switch picture

NEW Ruckus ICX-FAN11 Fan Tray module assembly For Brocade ICX7150-48ZP Switch

$119.95



Documentation

  • AIX Local Security Checks
  • Backdoors
  • CentOS Local Security Checks
  • CGI abuses
  • CISCO
  • Databases
  • Debian Local Security Checks
  • Default Unix Accounts
  • Denial of Service
  • Fedora Local Security Checks
  • Finger abuses
  • Firewalls
  • FreeBSD Local Security Checks